Technical Data - Foot column PJIB
PJIB
Technical Data
Product Dimensions


References | Product Dimensions [mm] | Holes | Bottom plate holes | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
A | B | C | D | E | F = g | G | t1 | t2 | Ø8.5 [mm] | Ø13 [mm] | |
PJIBG | 90 | 60 | 110 | 120 | 120 | 163 - 213 | 20 | 8 | 8 | 4 | 4 |
Capacities

References | Number of Fasteners | Characteristic capacities - Timber C24 [kN] | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
On post | On concrete | R1.k | R2.k | R3.k | R4.k | |||||||||||
Qty | Type | Qty | Type | Ø8x80 | Ø8x100 | Ø8x120 | min. g | max. g | min. g | max. g | ||||||
Ø8x80 | Ø8x100 | Ø8x120 | Ø8x80 | Ø8x100 | Ø8x120 | |||||||||||
PJIBG | 4 | Ø8 | 4 | Ø12 | min( 90.7 ; 54.5/kmod ) | 16 | 18.7 | 20.7 | 1.4/kmod | 1.1/kmod | min( 2 ; 1.6/kmod ) | min( 2.3 ; 1.8/kmod ) | min( 2.6 ; 1.8/kmod ) | min( 1.7 ; 1.4/kmod ) | min( 2 ; 1.4/kmod ) | min( 2.1 ; 1.4/kmod ) |
For the load directions R1.k and R3.k, the cpacities are valid for all length of steel dowel.
Load combinations: