Fasteners
  • When connecting beams in the same plane, CNA4.0 × 40/50 threaded nails or CSA5.0 × 35/40 screws are installed in the legs and CNA4.0 × 40 threaded nails or CSA5.0 × 35 screws in the body.
  • When connecting beams to concrete or masonry, CNA4.0 × 40 threaded nails or CSA5.0 × 35 screws are used.
  • In addition, special bolts are installed in the legs. The minimum bolt requirements must be observed.