Technical Data - PFU - purlin anchor

PFU

Technical Data

Dimensions

Dimensions - PFU - PFU - purlin anchor
product.image_with_dim.alt - PFU - PFU - purlin anchor
References DB. nr. NOB nr. Dimensions [mm] Holes
A B t Ø Qty
PFU170 5104561 44492696 170 30 2.0 5 3 + 3
PFU210 5385351 42290284 210 30 2.0 5 4 + 4
PFU250 1264631 44492700 250 30 2.0 5 5 + 5

Load Capacity Table (characteristic values)

Load Capacity Table (characteristic values) - PFU - PFU - purlin anchor
References Characteristic load-bearing capacity, two beam anchor price. collection [kN]
CNA4,0x40 [2 søm pr. flig] CNA4,0x40 [3 søm pr. flig] CNA4,0x40 [4 søm pr. flig] CNA4,0x40 [5 søm pr. flig]
R1,k - min af: R2,k=R3,k - min af: R1,k - min af: R2,k=R3,k - min af: R1,k - min af: R2,k=R3,k - min af: R1,k - min af: R2,k=R3,k - min af:
PFU170 5.5; 10.4/kmod 0.8; 9.5; 10.4/kmod 2.0 - - - -
PFU210 - - 9.6; 14.6/kmod 1.5 13.6: 14.6/kmod 3.1 - -
PFU250 - - - - 13.6; 14.6/kmod 2.6 17.6; 14.6/kmod 4.5

Kmod er modifikationsfaktoren for den lastgruppe, som den søgte bæreevne tilhører. Hvis åsen er forhindret i at rotere, vil bæreevnen R1,k, i en samling med kun et PFU bjælkeanker være halvdelen af bæreevnen.

R2,k = R3,k: det forudsættes, at kraften angriber max. 20 mm over bjælken. Søm placeres så tæt på underside ås/overside bjælke under hensyntagen til minimum kantafstande. Ved anvendelse af 4 stk. PFU bjælkeankre pr. samling kan tabelværdierne fordobles.